Home > Non-Contact Interlocks > F-Series > Safety Control Unit
F-SERIES SAFETY CONTROL UNIT
Description

The FM1 is the master control module for all F-Series Safety Systems. It contains the regulated power supply, 2 safety contact outputs (PGC), external/internal relay monitoring circuit and system indication along with the input for one safety switch sensor and it's
indication outputs.

The FM1 and one Safety Switch Sensor are all that is required for a system monitoring one guard. Simply clip the FM1 into a suitable control cabinet, fit the safety switch sensor to the guard and connect the supply and the volt free control contacts as shown in the installation guide.


For larger systems use the FX1 & FX2 Extender units with the FM1.

Dimensions
Dimensions
Control Category EN 954 CAT 4, SIL 3, PL-e
Power Consumption 100mA / 6VA
Supply Voltage 24VDC, 24VAC, 110VAC & 230VAC
Output Safety Contacts 2 x N/O
Safety Contact Switching 2A@230VAC or 30VDC
Safety Switch Inputs 1; Use FX1 & FX2 to build larger systems.
Indication Power, Run & Fault LED's; Gate Status LED & Volt Free Contacts
Dimensions 105 x 90 x 59mm
Mounting 35mm DIN Rail
IP Rating Housing IP40; Terminals IP20
Features External fault monitoring circuit, Manual monitored reset
Approvals TUV Category 4 & CE